HID Global

HID HID Global is the trusted leader in solutions for the delivery of secure identity solutions for millions of customers around the world and is committed to enhancing customer value by delivering the most trusted, advanced and dependable secure identity solutions in the market.


EDGE EVO®

  • Edge Evo

EH400-K Networked Controller

The EDGE EVO® EH400 is a single-door access control panel featuring Power over Ethernet (PoE). The EH400 makes local door decisions and can interface with one or two Hi-O iCLASS® readers.

  • Includes an optical tamper and interfaces to Hi-O compliant devices, including Hi-O readers, Hi-O REX, Hi-O Strike and Hi-O Interface Modules
  • Provides access control processing, host interface and power for a single door, including a separate HI-O iCLASS reader, Hi-O lock and Hi-O request-to-exit device
  • Basic package includes 1 reader, 4 inputs, 2 outputs, and optical tamper
  • Expandable to 2 readers, 16 inputs, and 6 outputs (with optional add-ons)
  • Interoperable with non-Hi-O door components with separately purchased Hi-O Interface Module
Data Sheet

EHR40-K Controller/Reader and Module

EDGE EVO® EHR40-K Controller/Reader and Interface Module package is a single-door access control panel with reader and separate discrete door interface. The controller/reader is installed at the door and the Hi-O Interface Module is mounted separately in a secure location.

  • The controller/reader and module are connected using the secure Hi-O bus and the Hi-O module provides interface to four discrete inputs and two outputs
  • An additional Hi-O iCLASS® reader can be attached to the EHR40-K controller/reader's Hi-O bus for in/out reading
  • The EHR40-K will accept either a second Hi-O iCLASS reader using the Hi-O bus or a Wiegand /Clock-and-Data reader through the use of a Wiegand Hi-O interface module
  • The integrated EDGE EVO® EHR40-K Controller/Reader also offers interface to 13.56 MHz compliant credentials, including iCLASS.
Data Sheet
  • EHRP40-K

EHRP40-K Controller/ Reader and Module

The EDGE EVO® EHRP40-K Controller/Reader and Interface Module package is a single-door access control panel with reader and separate discrete door interface that enables cost effective installation and high performance access control functionality. The controller/reader is installed at the door and the Hi-O Interface Module is mounted separately in a secure location.

  • The controller/reader and module are connected using the secure Hi-O bus and the Hi-O module provides interface to four discrete inputs and two outputs
  • The included Hi-O interface module provides interface to a second optional reader used for in/out reading
  • The integrated EDGE EVO® EHRP40-K Controller/Reader provides 13.56 MHz iCLASS smart card compatibility and controller logic in one device
  • Stores a complete access control and configuration database for one door with one or two readers and 125,000 cardholders
Data Sheet
  • EDWM-M

EDWM-M Door/ReaderModule

The EDWM-M Door and Reader module is designed for interfacing with the EDGE EVO Hi-O Networked Controller to electronic door components and a traditional Wiegand reader.

  • Provides four inputs, two outputs and Wiegand/Clock-and-Data reader interface.
  • Configure the Door component in two ways; as a primary door interface to REX, Door Position Switch, Battery Fail, Power Fail, Lock, and Aux (Group 1) or as a general purpose input/output module (Group 2)
  • Configure the Reader Module in two ways, either a Group 1 or Group 2 device. When two readers are present at one access control point, the secure reader side is assigned Group 1
Data Sheet
  • EDM-M

EDM-M Door Module

The EDM-M Door Module is wired to interface with the EDGE EVO device (Hi-O Networked Controller & Reader or Networked Controller) with electronic door components. Designed for providing interface to traditional discrete access inputs and outputs, the Door Module provides four input analog/digital inputs and two outputs.

  • Provides interface of up to four inputs and two outputs (for door specific use or general purpose)
  • Configure the Door Module in two ways; as a primary door interface to REX, Door Position Switch, Battery Fail, Power Fail, Lock, and Aux (Group 1) or as a general purpose input/output module (Group 2).
Data Sheet
  • EWM-M

EWM-M Wiegand Module

The EWM-M Wiegand Module is wired to interface with the EDGE EVO device (Hi-O Networked Controller & Reader or Networked Controller) with electronic door components. Designed for providing interface to traditional discrete access inputs and outputs, the Door Module provides four input analog/digital inputs and two outputs.

  • Provides interface of up to four inputs and two outputs (for door specific use or general purpose)
  • Configure the Door Module in two ways; as a primary door interface to REX, Door Position Switch, Battery Fail, Power Fail, Lock, and Aux (Group 1) or as a general purpose input/output module (Group 2).
Data Sheet
  • ELM

ELM Lock Module

The ELM Lock Module is a Hi-O interface module is wired to interface the EDGE EVO device (Controller/Reader & Module or Networked) with electronic door components.. Primary use is single (1) lock output.For mount in US single-gang electrical box, hollow door frame or other location. Hi-O compliant.

  • Interface to a single lock / AUX output
  • The Lock module provides outputs to an electronic locking device is a Hi-O to single (1) output interface
  • Output can be re-purposed for general purpose (Hi-O Group 2 configuration)
Data Sheet
  • EIM-M

EIM-M Input Module

The EIM-M Input Module is a Hi-O to discrete input. Inputs are 4 external inputs; onboard optical tamper (standard mount). Hi-O compliant. For use indoor or outside in weatherproof enclosure. IO is always general purpose (Hi-O Group 1 or 2 configuration).

  • Input Module provides an interface to four input analog/digital inputs
  • The module is always configured as general purpose input
  • Onboard optical tamper
Data Sheet

VertX EVO®

  • V1000

VertX EVO V1000 Networked Controller

The VertX EVO™ V1000 is a networked access controller with a multi-door access control panel. It reduces the burden on corporate Local Area Networks (LANs) by connecting up to 32 door controllers using only one IP address.VertX EVO V1000 makes all online door decisions, input monitoring and output control for all connected interface modules, including VertX® V100 (door interface), V200 (input monitor) and V300 (output control).The V1000 has two on-board inputs and outputs for local input point monitoring and auxiliary output control, and is powered by a local power supply (12 or 24 VDC).

  • Provides a complete and fully functional hardware/firmware infrastructure for access control software host systems
  • Stores a complete access control and configuration database for up to 32 Reader Interfaces (up to 64 doors) and 250,000 cardholders
  • Connects to the host and other devices on a TCP/IP network
  • Receives and processes real-time commands from the host software application
  • Access control system interfaces with combinations of devices with a maximum of 32
Data Sheet
  • V2000

VertX EVO V2000 Reader Interface/Networked Controller

VertX EVO™ V2000 is a two-reader access control panel that enables interface with two doors (single reader) or one door (in/out reading).The EVO V2000 handles all online door decisions, door input monitoring and output control and reader interface for up to two doors. The solution has two inputs per door for door monitor and REX, and two outputs per door for lock and AUX.VertX EVO V2000 also includes three inputs for AC power fail, Battery power fail and Tamper, and is powered by a local power supply (12 or 24 VDC).

  • Stores a complete access control and configuration database for up to 2 Reader Interfaces (up to 2 doors) and 250,000 cardholders
  • Connects to the host and other devices on a TCP/IP network
  • Receives and processes real-time commands from the host software application
  • Interface for two Wiegand or Clock-and-Data readers; inputs for 2 door monitors, 2 REX switches, AC fail, Battery fail and Tamper
  • Non-latching relay outputs rated 2 A @ 30 VDC : 2 door strikes (configurable) and 2 auxiliary devices (door held/forced alarm, alarm shunt, host offline (communication down),or general purpose)
Data Sheet
  • V100

V100 Door/ Reader Interface

The V100 Door / Reader Interface connects two access control card readers via Wiegand or Clock-and-Data interface controlling either one or two doors. The V100 features on-board flash memory, allowing program updates to be downloaded via the network. The V100 connects to the V1000 through a high speed RS-485 network. The V1000, in turn, communicates with the system host via industry standard TCP/IP protocol over 10/100 Mbps Ethernet or the Internet. This architecture minimizes the impact on corporate LANs by using only one TCP/IP address for every 32 interfaces and by handling low-level transactions on the RS-485 network.

  • Reports supervised inputs
  • Connects to the V1000 via RS-485
  • Receives and processes real time commands from the V1000
  • Reports all activity to the V1000
  • Processes off-line access control decisions based on facility code
  • UL 294 and UL 1076 recognized components
Data Sheet
  • V200

V200 Input Monitor Interface

The V200 input monitor interface connects up to 16 supervised input circuits. Each input point monitors and reports normal, off-normal, and alarm states. The V200 features on-board flash memory, allowing program updates to be downloaded through the network. The V200 connects to the V1000 via a high speed RS-485 network. The V1000, in turn, communicates with the system host via industry standard TCP/IP protocol, over 10/100 Mbps Ethernet, or the Internet. This architecture minimizes the impact on corporate LANs, by using only one TCP/IP address for every 32 interfaces, and by handling low-level transactions on the RS-485 network.

  • Reports supervised or un-supervised alarm circuits
  • Off-normal condition programmable for each input point (NO or NC alarm devices may be used)
  • Connects to the V1000 via RS-485
  • Receives and processes real time commands from the V1000
  • Reports all activity to the V1000
  • Allows complex input/output linking when used with the V1000 and V300 Output Control Interface
  • UL 294 and UL 1076 recognized components
Data Sheet
  • V300

V300 Output Control Interface

The V300 output control interface contains 12 latching Form-C relays, which can connect up to 12 devices controllable by simple contact closures, such as logic inputs for process equipment, HVAC and elevator control panels, CCTV switchers, etc.The V300 features on-board flash memory, allowing program updates to be downloaded via the network. The V300 connects to the V1000 through a high speed RS-485 network. The V1000 communicates with the system host via industry standard TCP/IP protocol over 10/100 Mbps Ethernet or the Internet. This architecture minimizes the impact on corporate LANs, by using only one TCP/IP address for every 32 Interfaces, and by handling low-level transactions on the RS-485 network.

  • Off-normal status programmable for each input point (NO or NC alarm devices may be used)
  • 12 latching Form-C relays, contacts rated at 2A @ 30VDC
  • Connects to the V1000 via RS-485
  • Receives and processes real time commands from the V1000
  • Reports all activity to the V1000
  • Allows complex input/output linking when used with the V1000 and V200
  • UL 294 and UL 1076 recognized components
Data Sheet

Newsletter

Keep up on our always evolving product features and technology. Enter your e-mail and subscribe to our newsletter.

About Our Company

Our vision is to lead the development of the next generation intelligent security systems that enable security stakeholders of organizations around the world make world a safer place.

Get in touch

  • Address: 7045 Tranmere Drive, Unit 8, Mississagua, Ontario, Canada

  • Phone: (416) 792-9110

  • Email: info@averics.com


Become a Dealer

Contact us today to become an Averics certified dealer.